1 This practice is under the jurisdiction of ASTM Committee A01 on Steel, Last previous edition approved in as A – 99 (). May 2nd, – Below is a technical summary of specification ASTM A 99 Advanced Plating Technologies is not. Gold plating is an exceptional finish for. BOOK ID: ECUadPJ && Download Book Pdf Astm A Finish Free. Passivation Services – Welcome to Scott Metal Finishing. ASTM A 99 Advanced.

Author: Jurg Taugul
Country: Poland
Language: English (Spanish)
Genre: Music
Published (Last): 8 June 2008
Pages: 109
PDF File Size: 6.57 Mb
ePub File Size: 12.31 Mb
ISBN: 347-7-53269-366-3
Downloads: 63244
Price: Free* [*Free Regsitration Required]
Uploader: Akigis

ASTM A380 Passivation Standard

It was at one time considered that an oxidizing treatment was necessary to establish this passive film, but it is now accepted that this film will form spontaneously in an oxygen-containing environment providing that the surface has been thoroughly cleaned or descaled. In order to avoid ambiguity in the setting of requirements, it s380 be necessary for the purchaser to define precisely the intended meaning of passivation.

The treatments are then defined by the process classes. For certain exceptional applications, additional requirements which are not covered by this practice may be specified upon agreement between the manufacturer and the purchaser.

Meaningful tests to establish the degree of cleanness of a surface are few, and those are often difficult to administer and to evaluate objectively. In some cases, no more than degreasing or removal of gross contamination is necessary.

Others, such as food-handling, pharmaceutical, aerospace, and certain nuclear applications, may require extremely high asmt of cleanness, including removal of all detectable residual chemical films and contaminants that are invisible to ordinary inspection methods.

These recommendations are presented as procedures for guidance when it is recognized that for a particular service it is desired to remove surface contaminants that may impair the normal corrosion resistance, or result in the later contamination of the particular stainless steel grade, or cause product contamination.

Parts treated however must pass specific tests to confirm the effectiveness of the passivation, although in practice the tests are for the detection of the effects of residual iron contamination on the surface of the parts.

  HAN CARLSON ADDER PDF

Some of the various meanings associated with the term passivation that are in common usage include the following: In addition, visual inspection of internal surfaces is often impossible because of the configuration of the item.

Passivation treatments are sometimes specified, but it is important to consider whether this is strictly necessary or not. Although they apply primarily to materials in the composition ranges of the austenitic, ferritic, and martensitic stainless steels, the practices described awtm also be useful for cleaning other metals if due consideration is given to corrosion and possible metallurgical effects.

The term “iron,” when hereinafter referred to as a surface contaminant, shall denote free 3a80. In addition, this standard also includes citric acid treatments. Citric acid passivation as an alternative to nitric acid treatments Citric acid treatments can also be considered as an alternative to nitric acid as both provide the oxidising conditions necessary for passivation.

Featured Articles & Publications

Pickling, passivation and removing iron contamination with nitric acid Passivation treatments are sometimes specified, but it is important to consider whether this asttm strictly necessary or not. It therefore in no way 9 the necessity for careful planning and judgment in the selection and implementation of such procedures.

Specifications for passivation treatments for stainless steels Traditionally the American standards have been used. Naturally occurring conditions such air or aerated water will do this and so under many exposure conditions stainless steels will naturally self-passivate.

Specific treatments are however also specified. This standard covers both nitric and citric acid treatments. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Stainless steels cannot be passivated unless the steel surface is clean and free from contamination and scale from welding operations. Stainless steels are designed to naturally self-passivate whenever a clean surface is exposed to an environment that can provide enough oxygen to form the chromium rich oxide surface layer, on which the corrosion resistance of these alloys depends.

Citric acid is a less hazardous method and has environmental benefits in terms of ‘NOx’ fume emission and waste acid disposal.

  EMOTIONAL BRANDING BY MARC GOBE PDF

Link to Active This link will always route to the current Active version of the standard. On the other hand, some of the practices may be applicable for these purposes.

Article: Passivation of stainless steels

Nitric acid alone can be used to remove light surface iron contamination after which the acid wstm the passivation of the cleaned steel surface. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Methods are described for the detection of free iron and transparent chemical and oily deposits.

Some of the various meanings associated with the term passivation that are in common usage include the following:. In the case of classes C3 and C4, a two step process is defined, with a clean water rinse between the two steps, shown in the table below. Passivation of stainless steels Introduction Stainless steels are designed to naturally self-passivate whenever a clean surface is exposed asym an environment that can provide enough oxygen to form the chromium rich oxide surface layer, on which the corrosion resistance of these alloys depends.

Citric acid treatments can also be considered aetm an alternative to nitric acid as both provide the oxidising conditions necessary for passivation. The standard also allows any combination of citric acid a3880, temperature and time, provided that the passivation test criteria can be met.

Visual inspection is suitable for the detection of gross contamination, scale, rust, and particulates, but may not reveal the presence of thin films of oil or residual chemical films. Range C Time mins. This process is described in a general way in 6. Office and Postal Address: For more specific safety precautions see 7. Such chemical treatment is generally not necessary for the formation of the passive film.